The SALICRU SLC-1500-TWIN RT2 LION is a 1500 VA / 1350 W On-line double-conversion UPS with a pure sine-wave output and 0.9 output power factor. Continuous operation through the rectifier and inverter isolates protected loads from mains disturbances and provides 0 ms transfer time if the input supply fails.
The input includes PFC, with a power factor of ≥0.99 at full load and THDi of ≤5%. Its wide input-voltage range reduces unnecessary battery use during mains fluctuations. ECO mode and frequency-converter operation are also available.
Backup power is provided by a LiFePO₄ battery rated at 48 V / 5 Ah. This technology provides high energy density, more than 2000 discharge cycles according to the series documentation and faster charging than the VRLA batteries traditionally used in UPS systems.
The convertible 2U chassis can be installed as a tower or in a 19-inch rack. Tower supports and rack-mounting ears are supplied, while the LCD can be rotated to match the equipment orientation. Internal rack rails are optional.
Eight IEC C13 outputs are provided: four for critical loads and four programmable outputs for non-critical loads. The latter can be disconnected during battery operation to reserve available energy for priority equipment.
USB-HID and RS-232 interfaces provide software monitoring and management. The intelligent slot supports optional relay, SNMP or RS485 Modbus cards. EPO and RJ45 protection for ADSL, fax or modem lines are also included.
It is suitable for servers, voice and data networks, storage systems, unified communications, streaming, document management, CAD/CAM and other IT applications requiring continuous high-quality power.
| Electrónica Embajadores reference | SA81LI150 |
| Salicru model | SLC-1500-TWIN RT2 LION |
| Salicru reference | 698LA000002 |
| Technology | On-line double conversion, PFC and dual DC bus |
| Input / output topology | Single-phase / single-phase |
| Format | Convertible tower / rack, 2U |
| Power rating | 1500 VA / 1350 W |
| Rated input voltage | 200 / 208 / 220 / 230 / 240 V AC |
| Input voltage range | 160–300 V AC at 100% load; down to 110 V AC at ≤60% load |
| Input frequency | 50 / 60 Hz, auto-detect |
| Input frequency range | ±10 Hz; 40–60 Hz / 50–70 Hz |
| Input harmonic distortion (THDi) | ≤5% at full load |
| Input power factor | ≥0.99 at full load |
| Output waveform | Pure sine wave |
| Output power factor | 0.9 |
| Rated output voltage | 200 / 208 / 220 / 230 / 240 V AC |
| Power derating at 200 / 208 V | 90% of rated power |
| Output voltage accuracy | ±1% |
| Output harmonic distortion (THDv) | ≤2% with linear load; <4% with non-linear load |
| Output frequency with mains present | Synchronised, 47–53 Hz / 57–63 Hz |
| Output frequency in battery mode | 50 / 60 Hz ±0.1 Hz |
| Inverter / battery transfer time | 0 ms |
| Full-load On-line efficiency | >90% |
| ECO-mode efficiency | >96% |
| Crest factor | 3:1 |
| Static bypass | Yes |
| Programmable outputs | Yes; 4 critical loads + 4 programmable/non-critical loads |
| Battery type | LiFePO₄ |
| Battery model and configuration | LiFe-48500 × 1 |
| Battery voltage / capacity | 48 V / 5 Ah |
| Total battery-group capacity | 5 Ah |
| End-of-backup cut-off voltage | 39.8 V DC |
| Discharge cycles | >2000 |
| Charger voltage | 52.5 V DC |
| Charging current | 1 / 2 / 4 / 6 / 8 A; 4 A default |
| Recharge time | Up to 3 h to 100% |
| Input connector | IEC C14, 10 A |
| Output connectors | 8 × IEC C13, 10 A |
| Communication ports | USB-HID and RS-232 DB9, mutually exclusive operation |
| Intelligent slot | Yes; optional relay, SNMP or RS485 Modbus cards |
| Monitoring software | ViewPower |
| Operating systems | Windows, Linux and Mac |
| Data-line protection | ADSL / fax / modem via RJ45 |
| Cold Start | Yes |
| EPO emergency power off | Yes |
| ECO mode | Yes |
| Frequency converter | Yes |
| Control panel | Rotatable LCD and keypad |
| Protection rating | IP20 |
| Operating temperature | 0–40 °C |
| Storage temperature | −15–50 °C |
| Relative humidity | 0–95%, non-condensing |
| Maximum operating altitude | 2400 m; power derating up to 5000 m |
| Acoustic noise at 1 m | <50 dB |
| Dimensions (depth × width × height) | 410 × 438 × 88 mm |
| Front projection in rack installation | 35 mm additional to stated depth |
| Rack height | 2U |
| Weight | 11.6 kg |
| Safety | EN-IEC 62040-1 |
| Electromagnetic compatibility | EN-IEC 62040-2, category C2 |
| Performance classification | EN-IEC 62040-3, VFI-SS-11 |