universal AC input / full range
cooling: by free air convection
LED indicator for power on
100 % full load burn-in test
using 105 °C long-life electrolytic capacitors
withstands 300 VAC surge input for 5 seconds
high operating temperature up to 70 °C
withstands 5G vibration test
no load power consumption < 0.5 W
high efficiency, long life and high reliability
3 years warranty
protection against: short circuit / overload / overvoltage
for professional use only
This Device must be installed by a qualified person.
output:
DC voltage: 12 V
rated Current: 1.3 A
Current range: 0-1.3 A
rated power: 15.6 W
ripple & noise (max.): 120 mVp-p
voltage adj. range: 10.8-13.2 V
voltage tolerance: ± 1.0 %
line regulation: ± 0.5 %
load regulation: ± 0.5 %
setup, rise time:
1000 ms, 30 ms / 230 VAC
1000 ms, 30 ms / 115 VAC at full load
hold up time (typ.):
70 ms / 230 VAC
12 ms / 115 VAC at full load
input:
voltage range:
85-264 VAC
120-370 VDC
frequency range: 47-63 Hz
efficiency (typ.): 81 %
AC Current (typ.):
0.35 A / 115 VAC
0.25 A / 230 VAC
inrush Current (typ.): cold start 65 A / 240 VAC
leakage Current: < 2 mA / 240 VAC
protection:
overload:
above 105 % rated output power
protection type: hiccup mode, recovers automatically after fault condition is removed
overvoltage:
13.8-16.2 V
protection type: shuts off output voltage, clamping by zener diode
overheating:
U1 Tj 140 °C typically (U1) detection on main control IC
protection type: shuts off output voltage, recovers automaticallly after temperature goes down
environment:
operating temperature: -25 to +70 °C
operating humidity: 20-90 % RH non-condensing
storage: -40 to +85 °C, 10-95 % RH
temperature coefficient: ± 0.03 %/°C (0-50 °C)
vibration: 10-500 Hz, 5G 10 min/1 cycle, period for 60 min each along X, Y, Z axes
safety & EMC:
safety standards: UL60950-1, TÜV EN60950-1 approved
withstand voltage:
input to output: 3 kVAC
input to ground: 2 kVAC
output to ground: 0.5 kVAC
isolation resistance: input to output, input to ground, output to ground: 100 Mohm / 500 VDC / 25 °C / 70 % RH
EMC emission: compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC immunity: compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
other:
MTBF: min. 1,608,800 h, MIL-HDBK-217F (25 °C)
dimensions: 62.5 x 51 x 28 mm
weight: 0.13 kg