Sold out. We can let you know when it is available.
This tower-format uninterruptible power supply (UPS) uses line-interactive technology and is rated at 1 500 VA / 900 W. This black version provides 6 IEC output sockets and is intended to protect computers, monitors, peripherals and other home, office or small-retail IT equipment against mains failures and voltage fluctuations.
Automatic AVR Buck/Boost regulation compensates for certain mains fluctuations without continuously drawing on the battery. If utility power fails, the UPS transfers to battery operation in 2–6 ms typical —10 ms maximum— and supplies a simulated sine-wave output. It is not an online double-conversion UPS.
The connected load must remain within both the 1 500 VA apparent-power rating and the 900 W active-power rating. Multiple sockets make it easier to connect equipment but do not increase the available power. Runtime depends on load, battery condition and operating conditions and must not be treated as a fixed value. The manual instructs users not to connect laser printers or scanners and recommends avoiding loads with incompatible starting surges.
The UPS contains two sealed, maintenance-free 9 Ah lead-calcium batteries with a stated design life of 3–5 years. Recharge to 90% capacity takes 4–6 hours. Cold start and automatic restart after the battery is exhaustd and mains power returns are supported. The battery is described as user-replaceable, but replacement must follow the manual and safety instructions; internal servicing is reserved for qualified personnel.
USB HID communication supports UPS monitoring, parameter configuration and controlled computer shutdown or hibernation using software compatible with Windows, Linux, Unix and Mac. LED indicators and audible alarms report mains operation, AVR regulation, battery operation, low battery, overload, fault and battery-replacement conditions.
The rear panel includes an IEC C14 inlet, 6 IEC output sockets, a USB HID port and a cooling fan. Protection is provided against overload, short circuit, transients, battery over-discharge and charger overcurrent. The documented package contents include two IEC output leads for this version.
Install the UPS on a stable, dry and ventilated surface, connect it to a protective-earthed outlet and leave at least 20 cm clearance for airflow. Before first use, or after more than two months without use, the product-specific manual specifies charging the batteries for at least four hours. The outputs may remain energised from the batteries even when the UPS is disconnected from the mains; do not open or work inside the unit.
| Brand | SALICRU |
| Model | SPS 1500 ONE BL IEC |
| Manufacturer part number | 662AG000014 |
| Colour | Black |
| Technology | Line-interactive |
| Form factor | Tower |
| Apparent power | 1 500 VA |
| Active power | 900 W |
| Nominal input voltage | 220 / 230 / 240 V AC |
| Input voltage range | 162–290 V AC |
| Nominal input frequency | 50 / 60 Hz |
| Automatic frequency detection | Yes |
| Voltage regulation | AVR Buck/Boost |
| Nominal output voltage | 220 / 230 / 240 V AC |
| Output accuracy in battery mode | ±10 % |
| Output frequency in battery mode | 50 / 60 Hz ±1 Hz |
| Waveform in battery mode | Simulated sine wave |
| Transfer time | 2–6 ms typical; 10 ms maximum |
| Input connection | IEC C14 inlet |
| Output sockets | 6 × IEC |
| Battery type | Sealed, maintenance-free lead-calcium |
| Installed batteries | 2 × 9 Ah |
| Battery design life | 3–5 years |
| Recharge time | 4–6 h to 90 % capacity |
| Replaceable battery | Yes; in accordance with the manual and safety instructions |
| Battery-replacement warning | Yes |
| Cold start | Yes |
| Automatic restart | Yes, when mains power returns after end of runtime |
| Communication | USB HID |
| Monitoring software | Compatible with Windows, Linux, Unix and Mac |
| Indicators | LEDs for mains, AVR, battery and fault |
| Audible alarms | Battery mode, low battery, overload, fault and battery replacement |
| Cooling | Built-in fan |
| Protection | Overload, short circuit, transients, battery over-discharge and charger overcurrent |
| Operating temperature | 0 to +40 °C |
| Relative humidity | Up to 90 %, non-condensing |
| Maximum operating altitude | 2 400 m above sea level |
| Acoustic noise at 1 m | < 40 dB(A) |
| Applicable standards | EN IEC 62040-1, EN IEC 62040-2 and EN IEC 62040-3 |
| Dimensions —depth × width × height— | 320 × 130 × 182 mm |
| Net weight | 10.4 kg |
| Documented package contents | UPS, quick-start guide, USB HID cable and 2 IEC output leads |