Available
The Omron G2R-2 110VAC is a general-purpose monostable electromechanical power relay with two changeover poles in a DPDT (2 CO) arrangement. It has eight straight pins and can be mounted directly on a printed circuit board (PCB) or inserted into a compatible socket.
For control-panel installations it can, for example, be used with a compatible DIN-rail socket for 2-contact relays, allowing the wiring to remain on the socket and the relay to be replaced without desoldering.
Omron officially identifies the coil for this variant as 100/(110) V AC. This designation represents 100 V AC at 50 Hz, 100 V AC at 60 Hz and 110 V AC at 60 Hz. The 110 V AC rating is therefore specified at 60 Hz and must not be interpreted as a 110 V AC 50/60 Hz rating.
Rated coil current is 11 mA at 100 V AC/50 Hz, 9 mA at 100 V AC/60 Hz and 10.6 mA at 110 V AC/60 Hz. The stated coil resistance is 4 600 Ω. The must-operate voltage is no more than 80 % of rated voltage and the must-release voltage is at least 30 %. At 23 °C, maximum coil voltage is 140 % of rated voltage; this is the maximum within a varying operating voltage range and is not a continuous voltage rating.
Switching capacity depends on load type. With a resistive load, the contacts are rated at 5 A at 250 V AC or 5 A at 30 V DC. With an inductive load, the ratings are 2 A at 250 V AC with cos φ = 0.4 and 3 A at 30 V DC with L/R = 7 ms. The 5 A figure must therefore not be interpreted as a rating that applies indiscriminately to every type of load.
The relay provides 5 kV AC dielectric strength between the coil and contacts and 3 kV AC between contacts of different polarity. It can operate from −40 °C to 70 °C and has a minimum mechanical endurance of 10 000 000 operations for the AC-coil version.
| Brand | Omron |
| Model | G2R-2 110VAC |
| Electrónica Embajadores code | RL3A865 |
| Series | G2R |
| Type | General-purpose electromechanical power relay |
| Relay function | Monostable |
| Contact configuration | DPDT, 2 CO (2 changeover contacts) |
| Number of poles | 2 |
| Number of pins | 8 |
| Terminal type | Straight pins |
| Mounting | Direct PCB mounting or compatible socket, including DIN-rail sockets |
| Enclosure protection | Flux protected |
| Coil polarity | Non-polarised |
| Rated coil designation | 100/(110) V AC |
| Rated voltage/frequency conditions | 100 V AC at 50 Hz; 100 V AC at 60 Hz; 110 V AC at 60 Hz |
| Rated coil current | 11 mA at 100 V AC/50 Hz; 9 mA at 100 V AC/60 Hz; 10.6 mA at 110 V AC/60 Hz |
| Coil resistance | 4 600 Ω, reference value |
| Must-operate voltage | ≤ 80 % of rated voltage |
| Must-release voltage | ≥ 30 % of rated voltage |
| Maximum coil voltage | 140 % of rated voltage at 23 °C; maximum within a varying operating voltage range, not a continuous rating |
| Rated resistive load | 5 A at 250 V AC; 5 A at 30 V DC |
| Rated inductive load | 2 A at 250 V AC (cos φ = 0.4); 3 A at 30 V DC (L/R = 7 ms) |
| Rated carry current | 5 A |
| Maximum switching current | 5 A |
| Maximum switching voltage | 380 V AC; 125 V DC |
| Maximum switching power, resistive load | 1 250 VA; 150 W |
| Maximum switching power, inductive load | 500 VA; 90 W |
| Contact resistance | ≤ 50 mΩ, initial value |
| Operate time | ≤ 15 ms |
| Release time | ≤ 10 ms, AC coil |
| Insulation resistance | ≥ 1 000 MΩ at 500 V DC, initial value |
| Dielectric strength, coil to contacts | 5 kV AC, 50/60 Hz, for 1 min |
| Dielectric strength between contacts of different polarity | 3 kV AC, 50/60 Hz, for 1 min |
| Dielectric strength between contacts of the same polarity | 1 kV AC, 50/60 Hz, for 1 min |
| Mechanical endurance | ≥ 10 000 000 operations, AC coil, at 18 000 operations/h |
| Electrical endurance | ≥ 100 000 operations, at 1 800 operations/h under rated load |
| Operating temperature | −40–70 °C, with no icing |
| Operating humidity | 5 %–85 % |
| Maximum dimensions | 29 × 13 × 25.5 mm |
| Weight | Approximately 17 g |