True RMS AC Digital Clamp Meter
LCD display / 6000 counts
Maxillary diameter Ø 26mm
AC Amperage measurement up to 600A
Range:
6A, precision +-2.5%
60A, precision +-2, 5%
600A, precision +-3%
AC/DC voltage measurement up to 600V
AC range:
6V, resolution 0.001V, precision +-0.8% +- 5 digits
60V, resolution 0.01V, precision +-0.8% +- 5 digits
600V, resolution 0.1V, precision +-0.8% +- 5 digits
Resistance measurement up to 60MOhm
Range:
600 ohms, resolution 0.1 ohms precision +-1% +- 5 digits
6K, resolution 0.001K precision +-1% +- 5 digits
60k , resolution 0.01K precision +-1% +- 5 digits
600K, resolution 0.1K precision +-1% +- 5 digits
6M, resolution 0.001M precision +-1% +- 5 digits
60M, resolution 0.01M precision +-1% +- 5 digits
Frequency measurement from 10Hz to 10MHz
Range:
10Hz, resolution 0.001Hz precision +-1% +- 3 digits
100Hz, resolution 0.01Hz precision +-1% +- 3 digits
1000Hz, resolution 0.1Hz precision +-1% +- 3 digits os
10KHz, resolution 0.001KHz precision +-1% +- 3 digits
100KHz, resolution 0.01KHz precision +-1% +- 3 digits
1000KHz, resolution 0.01KHz precision + -1% +- 3 digits
Capacity measurement up to 100mF
Range:
10nF, resolution 0.001nF precision +-4% +- 5 digits
100nF, resolution 0.01nF precision +- 4% +- 5 digits
1000nF, resolution 0.1nF precision +-4% +- 5 digits
10uF, resolution 0.001uF precision +-4% +- 5 digits
100uF, resolution 0.01uF precision +-4% +- 5 digits
1000uF, resolution 0.1uF precision +-4% +- 5 digits
10mF, resolution 0.001mF precision +-4% +- 5 digits
100mF, resolution 0.01mF accuracy +-4% +- 5 digits
Diode test
Low Pass Filter (LPF)
Low impedance voltage measurement (LowZ)
Non-contact voltage detector
Continuity test with acoustic warning
Illuminated display
Flashlight function
Temperature: 1000º
MAX. / MIN.
Auto power off
Power supply 2 batteries 1.5V type AAA
Dimensions: 193 x 73 x 34 mm