Sold out. We can let you know when it is available.
Portable 3-in-1 instrument combining a 2-channel digital oscilloscope, TRMS multimeter and DDS function generator, intended for diagnostics, maintenance, laboratory work, training and electronic development.
The oscilloscope provides 50 MHz analogue bandwidth and 250 MSa/s real-time sampling, with two input channels, 8-bit vertical resolution, capture depth up to 64 kByte, a 10 ns/div to 10 s/div timebase and 10 mV/div to 10 V/div vertical sensitivity. Inputs support AC/DC coupling, 1×/10× probes and a 20 MHz bandwidth limit.
For signal analysis it provides Auto, Normal and Single triggering on rising or falling edges, Y-T, X-Y and roll display modes, cursors, persistence and mathematical operations between channels. FFT and automatic measurements include period, frequency, peak-to-peak, maximum, minimum, average, RMS, amplitude, duty cycle and pulse width.
Oscilloscope screenshots can be saved in BMP format for later review. USB sharing allows the instrument to appear as a storage drive on a computer for accessing screenshots and performing firmware updates.
The multimeter provides 4½ digits and 19,999 counts with TRMS measurement. It measures AC/DC voltage and current, resistance, capacitance and temperature, with diode and continuity tests. Auto mode recognises voltage and resistance and automatically distinguishes AC from DC voltage.
The built-in DDS generator provides 12 waveforms. Sine output reaches 10 MHz and the other waveform types up to 5 MHz, with 1 Hz frequency steps. Amplitude is adjustable from 0.1 to 3.0 V and square-wave duty cycle from 0 to 100%.
A 4.3-inch 480 × 272 colour IPS touchscreen provides adjustable brightness. The instrument measures approximately 145 × 98 × 35 mm, weighs about 360 g and offers an eight-language interface.
A built-in 4,000 mAh lithium battery is charged through USB-C at 5 V / 2 A. The manufacturer states up to approximately 4 h of operation. Charging should use an independent supply rather than power or USB from the equipment being tested.
The two oscilloscope channels share a common ground. When both channels are used, the two probe ground clips must be at the same potential and must not be connected to different potentials. The manual states a maximum of ±400 V at the oscilloscope input but does not declare a CAT measurement category, so this figure must not be interpreted as a mains-installation safety rating.
| Type | Portable 3-in-1 digital oscilloscope |
| Integrated functions | 2-channel oscilloscope + TRMS multimeter + DDS generator |
| Stated architecture | FPGA + MCU + ADC |
| Display | IPS táctil a color, 4,3 pulgadas |
| Display resolution | 480 × 272 píxeles |
| Brightness | Adjustable |
| Interface languages | Chinese, English, Russian, Japanese, Spanish, Portuguese, German and Korean |
| Battery | Rechargeable lithium, 4,000 mAh |
| Power / charging | USB-C, 5 V / 2 A |
| Stated operating time | Up to ≈4 h |
| Dimensions | ≈145 × 98 × 35 mm |
| Weight | ≈360 g |
| Operating temperature | −5 to +40 °C |
| Maximum operating relative humidity | 80 % |
| Oscilloscope: channels | 2 |
| Oscilloscope: bandwidth | 50 MHz |
| Oscilloscope: real-time sampling | 250 MSa/s |
| Oscilloscope: capture depth | Up to 64 kByte |
| Oscilloscope: timebase | 10 ns/div – 10 s/div |
| Oscilloscope: vertical sensitivity | 10 mV/div – 10 V/div |
| Oscilloscope: vertical resolution | 8 bits |
| Oscilloscope: input impedance | 1 MΩ |
| Oscilloscope: probe attenuation | 1× / 10× |
| Oscilloscope: input coupling | AC / DC |
| Oscilloscope: bandwidth limit | Selectable 20 MHz |
| Oscilloscope: trigger modes | Auto / Normal / Single |
| Oscilloscope: trigger type | Rising / falling edge |
| Oscilloscope: trigger-level range | 8 divisions, positive / negative |
| Oscilloscope: display modes | Y-T / X-Y / roll |
| Oscilloscope: stated maximum input voltage | ±400 V; does not imply a CAT rating |
| Oscilloscope: stated storage space | 13 M |
| Oscilloscope: automatic measurements | Period, frequency, Vpp, Vmax, Vmin, average, RMS, amplitude, duty cycle and pulse width |
| Oscilloscope: maths operations | 1+2, 1−2, 1×2, 1/2, −1, −2, |1|, |2| y FFT |
| Oscilloscope: cursors | X1−X2 / Y1−Y2 |
| Oscilloscope: persistence | 1 s / infinite |
| Screenshots | BMP |
| USB transfer / storage | Yes, via USB sharing mode |
| Multimeter: resolution | 4½ digits, 19,999 counts |
| Multimeter: measurement type | TRMS |
| DC voltage: ranges | 1.9999 / 19.999 / 199.99 / 1000.0 V |
| DC voltage: stated accuracy | ±(0.5% + 3) |
| AC voltage: ranges | 1.9999 / 19.999 / 199.99 / 750.0 V, according to the manual |
| AC voltage: stated accuracy | ±(1% + 3) |
| DC current: ranges | 19.999 mA / 199.99 mA / 1.9999 A / 9.999 A |
| DC current: stated accuracy | ±(1.2% + 3) |
| AC current: ranges | 19.999 mA / 199.99 mA / 1.9999 A / 9.999 A |
| AC current: stated accuracy | ±(1.5% + 3) |
| Resistance: ranges | 199.99 Ω / 1.9999 kΩ / 19.999 kΩ / 199.99 kΩ / 1.9999 MΩ / 19.999 MΩ |
| Resistance: stated accuracy | ±(0.5% + 3) at 199.99 Ω and 1.9999 kΩ; ±(1.5% + 3) at higher ranges |
| Capacitance: ranges | 9.999 nF / 99.99 nF / 999.9 nF / 9.999 µF / 99.99 µF / 999.9 µF / 9.999 mF / 99.99 mF |
| Capacitance: stated accuracy | ±(2.0% + 5) up to 999.9 µF; ±(5.0% + 20) at 9.999 mF and 99.99 mF |
| Temperature: range | −55 to +1300 °C / −67 to +2372 °F |
| Temperature: stated accuracy | ±(2.5% + 5) |
| Diode test | Yes |
| Continuity | Yes; audible alert when resistance is <50 Ω |
| Multimeter Auto mode | Recognises voltage and resistance; identifies AC/DC in voltage mode |
| Generator: type | DDS, 1 channel |
| Generator: number of waveforms | 12 |
| Generator: maximum sine frequency | 10 MHz |
| Generator: maximum frequency, other waveforms | 5 MHz |
| Generator: frequency range | 0 – 10 MHz |
| Generator: frequency step | 1 Hz |
| Generator: amplitude | 0.1 – 3.0 V |
| Generator: square-wave duty cycle | 0 – 100 % |
| Generator: waveforms | Sine, square, sawtooth, half-wave, full-wave, positive step, negative step, DC, exponential rise, exponential fall, multi-audio and sync pulse |
| CAT measurement category | Not specified in the reviewed manual/documentation |
| Oscilloscope common-ground safety | The 2 channels share common ground; do not connect the ground clips to different potentials |
| Supplied contents | Instrument, 2 P6100 probes, multimeter leads, alligator-clip lead, data cable, manual and storage case |