CAT III 600 V / CAT IV 300 V
auto/manual range
automatic polarity indication
automatic zero adjustment
voltage measurements: 600 VAC and 600 VDC max.
Current measurements: DC 15 A and AC 15 A max.
resistance measurements: 40 MOhm max.
with separate test leads (incl.): TLM72
pollution degree 2
Important safety information
DC voltage: 0-400 mV / 4 V / 40 V / 400 V / 600 V
basic accuracy: ± (0.5% rdg + 2 digits) , ±(0.8% rdg + 2 digits) for 600 V range
input impedance: >10 MOhm
maximum input: 600 V
AC voltage: 0-4 V / 40 V / 400 V / 600 V
basic accuracy: ± (0.8% rdg + 3 digits) , ±(1.2% rdg + 3 digits) for 600 V range
input impedance: 10 MOhm
frequency range: 40 - 500 Hz
maximum input: 600 V
DC Current: 0-400µA / 4 mA / 40 mA / 400 mA / 4 A / 15 A
basic accuracy: ± (1.2% rdg + 2 digits) , ±(2.0% rdg + 3 digits) for 4 A to 15 A range
overload protection: 0.5 A / 600 V fuse for µA to mA range, 15 A / 600 V fuse up to 15 A range
AC Current: 0-400µA / 4 mA / 40 mA / 400 mA / 4 A / 15 A
basic accuracy: ± (1.5% rdg + 3 digits) , ±(2.5% rdg + 5 digits) for 4 A to 15 A range
overload protection: 0.5 A / 600 V fuse for µA to mA range, 15 A / 600 V fuse up to 15 A range
frequency range: 40 - 500 Hz
resistance: 0-400 Ohm / 4 kOhm / 40 kOhm / 400 kOhm / 4 MOhm / 40 MOhm
basic accuracy: ± ( 1.0% rdg + 1 Ohm) for 0 to 400 Ohm range, ( 1.0% rdg + 2 digits) for 4 kOhm to 4 MOhm range, ± (1.5% rdg + 3 digits) for 40 MOhm range
overload protection: 0.5 A / 600 V fuse
capacitance: 0-40 nF / 400 nF / 4 µF / 40 µF / 100 µF
basic accuracy: ± ( 3.0% rdg + 10 digits) for 0 to 40 nF range, ( 2.5% rdg + 5 digits) for 400 nF to 40 µF range, ± (5.0% rdg + 10 digits) for 100 µF range
overload protection: 0.5 A / 600 V fuse
frequency: 0-10 Hz / 100 Hz / 1000 Hz / 10 kHz / 100 kHz / 1000 kHz / 10 MHz
basic accuracy: ± (0.1% rdg + 5 digits)
duty cycle: 0.1% - 99.9%
basic accuracy: ± (2.0% rdg + 2 digits)
frequency: < 10 kHz
temperature: -50 °C - 800 °C
basic accuracy: ± ( 3°C + 1 digit) for -50°C - 150°C, ( 3.0% rdg + 1 digit) for 150°C - 800°C
battery test: -
basic accuracy: -
overload protection: -
audible continuity measurement: built-in buzzer sounds if resistance is less than 30 Ohm
test voltage: approx. 0.5 V
diode measurement: test forward voltage of diode
test voltage: forward DC Current approx. 1 mA, reversed DC voltage approx. 1.5 V
overrange: yes
continuity buzzer: yes
transistor test: no
diode test: yes
low-battery indication: yes
maximum display: 3 ¾
LCD Display size:
size: 65 x 36 mm
digits: max. 3999
ranging mode: auto range and manual range
data hold: yes
backlight: yes
auto power-off: yes
operating environment:
temperature: 0 °C to 40 °C (32 °F to 104 °F)
humidity: < 80% RH
storage environment:
temperature: -20 °C to 60 °C (-4 °F to 140 °F)
humidity: < 90% RH
fuse:
F0.5 A / 600 V 5 x 20 mm
F15 A / 600 V 6 x 32 mm
test lead probe: CAT III 1000 V / CAT IV 600 V, 15 A, L = 75 cm
dimensions: 188 x 102 x 38 mm
weight (with battery): 325 g
power supply: 2 x AA LR6 (incl.)
packing: double blister
IP rating: IP20